Precision Water Meters for Every Application

From residential multi-jet meters to industrial electromagnetic flow meters — Nixies delivers accurate, durable water measurement solutions.

Product Lines
0 +
Size Range
15 - 0 mm
Certified Standard
ISO 0

Multi-Jet Class B Water Meter

A multi-jet, dry-dial meter with magnetic drive offering reliable performance and a long service life. The vacuum-sealed register keeps the dial fog and frost-free, ensuring clear readings throughout its lifetime.

Features

Working Conditions

Water temperature: 0.1°C – 50°C | Water pressure: ≤ 1.0 MPa or 1.6 MPa
Accessories included: With every meter — 2× nipples, 2× nuts, 2× gaskets (coupling set).
Multi-Jet Water Meter Flow Rate Specifications
Size (mm) Qmin (l/h) Qt (l/h) Qn (m³/h) Qmax (m³/h)
15 30 120 1.5 3
20 50 200 2.5 5
25 70 280 3.5 7
40 200 800 10 20
50 300 1200 15 30

Woltman type water meter

Features

Working Condition:

Woltman Type Water Meter Flow Rate Specifications
Line size Minimum flow rate
Qmin
(m³/h)
Transitional flow rate
Qt
(m³/h)
Nominal flow rate
Qn
(m³/h)
Maximum flow rate
Qmax
(m³/h)
40mm 0.5 0.8 25 31.25
50mm 0.5 0.8 40 50
65mm 0.7875 1.26 63 78.75
80mm 0.7875 1.26 63 78.75
100mm 1.25 2 100 125
125mm 2 3.2 160 200
150mm 3.125 5 250 312.5
200mm 5 8 400 500
250mm 7.875 12.6 630 787.5
300mm 12.5 20 1000 1250
350mm 12.5 20 1000 1250
400mm 20 32 1600 2000
500mm 31.25 50 2500 3125

Electromagnetic Flow Meter

Features

Power Supply AC220V 50Hz / DC24V / 3.5V
Power Consumption <15W (Supporting power consumption with sensors)
Display and Buttons Display in Chinese and English can display instantaneous flow, cumulative flow and alarm display (excitation open circuit alarm, empty pipe alarm, flow limit alarm). Four membrane touch switches for data setting.
Counter Forward total, reverse total
Output Signals Analog Output Two-way fully isolated 0-10mA / 4-20mA
Load resistance 0-1.5kΩ when 0-10mA, 0-750Ω when 4-20mA
Frequency Output Forward and reverse flow output. The upper limit of output frequency can be set within 1-5000Hz. Open collector bidirectional output of transistor with photoelectric isolation. External power supply is not greater than 35V, maximum collector current when conducting is 50mA.
Alarm Output Two open collector alarm outputs with photoelectric isolation transistors. External power supply is not greater than 35V and maximum collector current is 250mA. Alarm status includes empty pipe, excitation disconnection and flow overrun.
Pulse Output Forward and reverse flow output. Upper limit of output pulse can reach 5000CP/S. Pulse equivalent is 0.0001-1.0m²/P. Pulse width automatically set to 20ms or square wave. Open collector output with photoelectric isolation. External power supply is not greater than 35V, maximum collector current is 50mA.
Matching Accuracy 0.5% of measured value ±1mm/s, optional 0.3% of indicated value
Damping Time Constant Continuous variable from 0-100s (90%) time grading optional
Communication Optional RS232C or RS485 serial communication interface. HART communication protocol with anti-lightning protection.
Loss of Power Internal power-off clock can store 16 power interruption records (10 years).
Protection Level IP65
Explosion-proof Mark Exs(ia)(ia)c T5

Ultrasonic Water Meter

Features

Model X-15 X-20 X-25 X-32 X-40
Pipe Diameter DN15 DN20 DN25 DN32 DN40
Q1 (m³/h) @ R500 0.005 0.008 0.0126 0.02 0.032
Q2 (m³/h) 0.08 0.0128 0.02016 0.032 0.0512
Q3 (m³/h) 2.5 4.0 6.3 10 16
Connection G¾" G1" G1¼" G1½" G2"
Length (mm) 165 195 225 180 200
Width (mm) 81 81 81 81 81
Height (mm) 100 100 118 128 135
Temperature Medium Range: 0.1°C–30/50/70°C (T30 / T50 / T70)    Ambient Temperature: 5~55°C    Storage Temperature: -20~60°C
Materials Brass 59-1
Metrological Class Class 2 R160 / R200 / R250 / R400 / R500
Maximum Operation Pressure 1.6 MPa
Pressure Loss ΔP ≤ 40kPa
Pressure Stage PN16
Protection Class IP68
Stream Field Sensitivity U5 / D3
Battery (Optional) 6 / 10 / 16 Years Service Life
Data Storage (Optional) 24 / 120 Logs, Daily / Weekly / Monthly
Environmental Requirement E1, M1, B
Interface & Communication (Optional) M-Bus, Pulse Output, RS485, LPWAN (LoRaWAN, NB-IoT, Sigfox)
Installation 360 Degree

Ultrasonic Clamp-On Flow Meter

Features

Linearity 0.5%
Repeatability 0.2%
Accuracy ±1% of reading at rates > 0.2 mps
Response Time 0–999 seconds, user-configurable
Velocity ±32 m/s
Pipe Size 20mm – 6000mm
Rate Units Meter, Feet, Cubic Meter, Liter, Cubic Feet, USA Gallon, Imperial Gallon, Oil Barrel, USA Liquid Barrel, Imperial Liquid Barrel, Million USA Gallons. User configurable.
Totalizer 7-digit totals for net, positive and negative flow respectively
Liquid Types Virtually all liquids
Security Setup values modification lockout. Access code required for unlocking.
Display 4 × 16 English letters
Communication Interface RS-232C, baud rate from 75 to 57600. Protocol made by the manufacturer and compatible with FUJI ultrasonic flow meters. User protocols can be made on enquiry.
Transducers Model M1 as standard, 3 additional models optional
Cable Length Standard 2 × 10 meters, optional 2 × 500 meters
Power Supply 3 AAA Ni-H built-in batteries. When fully recharged, battery life exceeds 10 hours of operation. Charger input: 100V–240V AC.
Data Logger Built-in data logger can store over 2000 lines of data
Manual Totalizer 7-digit press-key-to-go totalizer for calibration
Housing Material ABS
Case Size 100 × 66 × 20 mm
Handset Weight 514g (1.2 lbs) with batteries

AMR Water Meter With Lora System

Automated meter reading (AMR) is the communication technology used by water utilities to autonomously collect water consumption data from water meters. The AMR systems can be drive-by or walk-by. The endpoint, connected to the meter’s encoder register, records water flow and alarm data further collected by utility personnel by driving or walking by with a data receiver close to the device.

Furthermore, automatic meter reading systems entail three primary components. These include a meter interface module with a communication interface, meter sensors, and power supply; communication systems used for telemetry or transmission of data and regulating signals between the central office and meter interface units; central office systems equipment that include controllers, data concentrators, receivers, modems, host computer, and host upload links.

Protection box

Brass ball valve

A brass ball valve is a type of valve that’s commonly used in plumbing and industrial systems to control the flow of liquids or gases.